Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 29
Filter
1.
Braz. dent. sci ; 26(1): 1-9, 2023. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1411424

ABSTRACT

Objective: Evaluate the mechanical properties of experimental adhesive models with different photoinitiators (PI) polymerized by LED units of different power densities. Material and Methods: Three groups of adhesive models based on HEMA/BisGMA (45/55) were prepared in association with different PI combinations: G2 (control) ­ 2 PI: 0.5% CQ, 0.5% EDMAB; G3 - 3 PI: 0.5% CQ; 0.5% DMAEMA, 0.5% DPIHP; G4 - 4 PI: 0.5% CQ; 0.5% EDMAB; 0.5% DMAEMA; 0.5% DPIHP. The three formulations were polymerized at two different LED power densities: 550 mW/cm2 and 1200 mW/cm2. The degree of conversion (DC) of adhesive monomers was monitored in situ through the FTIR for 600 s. Specimens were prepared for each formulation for analysis mong adhesive systems (G2

Objetivo: Avaliar as propriedades mecânicas de modelos adesivos experimentais com diferentes fotoiniciadores (PI) polimerizados por unidades de LED de diferentes densidades de energia. Material e Métodos: Três grupos de modelos adesivos baseados em HEMA/BisGMA (45/55) foram preparados em associação com diferentes combinações de PI: G2 (controle) ­ 2 PI: 0,5% CQ, 0,5% EDMAB; G3 - 3PI: 0,5% CQ; 0,5% DMAEMA, 0,5% DPIHP; G4 - 4 PI: 0,5% CQ; 0,5% EDMAB; 0,5% DMAEMA; 0,5% DPIHP. As três formulações foram polimerizadas em duas densidades de potência de LED: 550 mW/cm2 e 1200 mW/cm2. O grau de conversão (DC) dos monômeros adesivos foi monitorado in situ através do FTIR durante 600 s. Amostras foram preparadas para cada formulação para análise de resistência à flexão (FS), módulo de elasticidade (ME), sorção (SOR) e solubilidade (SOL). Os dados foram submetidos aos testes ANOVA 2-fatores e Tukey (5%). Resultados: DC: houve diferença significativa entre os sistemas adesivos (G2

Subject(s)
Radiation , Dentin-Bonding Agents , Light-Curing of Dental Adhesives , Photoinitiators, Dental
2.
Braz. dent. sci ; 25(1): 1-9, 2022. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1361885

ABSTRACT

Objetivo: O objetivo foi avaliar a resistência de união de seis adesivos experimentais contendo sistemas fotoiniciadores binários ou ternários, associados a três diferentes concentrações de MDP (0-12% em peso) após 12 meses de armazenamento em água destilada. Material e Métodos: Adesivos experimentais foram preparados com: bis-GMA, UDMA, bis-EMA, TEGDMA, HEMA, BHT e etanol, contendo sistemas fotoiniciadores binários (CQ/amina) ou ternários (CQ/amina/DPIHFP ­ 0,5% em peso). Foi adicionado a esta composição 0%, 6% ou 12% em peso de MDP. Os sistemas adesivos foram aplicados seguindo o protocolo com condicionamento ácido. Moldes cilíndricos transparentes foram colocados sobre a dentina hibridizada, preenchidos com resina composta e fotopolimerizados. Os corpos-de-prova foram armazenados em água destilada a 37oC por 24h ou 12 meses e submetidos ao ensaio de microcisalhamento (n=6). Os dados foram analisados por ANOVA de três fatores e teste de Tukey (α=5%). Resultados: Para o sistema binário, após 12 meses de armazenamento, todos os valores de resistência de união foram semelhantes. Em relação à degradação da resistência de adesão ao longo do tempo, as formulações de MDP de 6% e 12% mostraram resistência de união mais estável do que 0% de MDP. Para o sistema ternário, todas as formulações (0%, 6% e 12% em massa de MDP) mostraram resistência de união estável em função do tempo. Conclusão: Para o sistema binário, as concentrações de 6 e 12% em massa de MDP foram capazes de manter a resistência de união em função do tempo, enquanto que para o sistema ternário, a estabilidade de união foi obtida independentemente da concentração de MDP. Pode-se concluir que, para a formulação dos adesivos utilizados neste estudo, independente do sistema fotoiniciador, a concentração de 12% MDP apresentou valores de resistência de união mais estáveis após 12 meses de armazenamento em água (AU)


Objective: The aim was to evaluate the bond strength of six experimental adhesives containing binary or ternary photoinitiator systems, associated with three different MDP concentrations (0-12wt%) after 12 months of storage in distilled water. Material and Methods: Experimental adhesives were prepared with: bis-GMA, UDMA, bis-EMA, TEGDMA, HEMA, BHT, and ethanol, containing binary (CQ/amine) or ternary (CQ/amine/DPIHFP (diphenyliodonium hexafluorophosphate) ­ 0.5wt%) photoinitiator systems. It was added to this composition 0wt%, 6wt%, or 12wt% of MDP. The adhesive systems were applied following the etch-and-rinse protocol. Transparent cylindrical molds were placed on the hybridized dentin, filled with composite resin and light-cured. The specimens were stored in distilled water at 37oC for 24h or 12 months and submitted to a microshear bond strength test (n=6). Data were analyzed by three-way ANOVA and Tukey's test (α=5%). Results: For the binary system, after 12 months of storage, all bond strength values were similar. Regarding bond strength degradation over time, 6wt% and 12wt% MDP formulations showed more stable bond strength than 0wt% MDP. For the ternary system, all formulations (0wt%, 6wt% and 12wt%) showed stable bond strength over time. Conclusion: For the binary photoinitiator system, the 6wt% and 12wt% MDP concentrations were able to keep bond strength stable over time, while for the ternary system, bond strength stability was achieved regardless the MDP concentration. (AU)


Subject(s)
Dental Cements , Photoinitiators, Dental
3.
Braz. dent. sci ; 22(3): 395-407, 2019. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1009546

ABSTRACT

Objective: This study aimed to evaluate the effect of diode laser irradiation (970 nm) of a one-step self-etch adhesive (Clearfil S3 Bond/CS3B) and of the bonding agent of a two-step self-etch adhesive (Clearfil Liner Bond F/CLBF) placed on dentin before polymerization on the shear bond strength. Material and methods: Forty sound premolars were sectioned buccally to obtain flat dentin surfaces. The specimens were divided into 4 groups (n = 10): Group (OS) ­ CS3B + polymerization. Group (OS-L) ­ CS3B + laser + polymerization. Group (TS) ­ CLBF (bonding agent only) + polymerization. Group (TS-L) ­ CLBF (bonding agent only) + laser + polymerization. The diode laser was irradiated through an 8 mm bleaching tip for 10 seconds, (0.4 W, 10 Hz, 4 J). All samples were cemented to composite blocks and submitted to 4000 thermal cycles. The samples were tested for shear bond strength in a universal testing machine. Data obtained was analyzed using Twoway (ANOVA) (p < 0.05) and the Bonferroni posthoc test. Representative samples from each group were analyzed using scanning electron microscopy (SEM). Results: Group TS-L ­ (7.43 MPa) displayed statistically significant higher shear bond strength in comparison to that of group TS ­ (5.13 MPa). No statistically significant difference was found between group OS-L ­ (6.49 MPa) and group OS ­ (7.28 MPa). Group TS-L exhibited the highest resin penetration beyond the hybrid layer under SEM. Conclusions: Diode laser irradiation of a bonding agent placed on dentin without prior priming increased the bond strength to dentin and is promising as a new dentin adhesion protocol. (AU)


Objetivo: Este estudo teve como objetivo avaliar o efeito da irradiação com laser de diodo (970 nm) sobre um adesivo autocondicionante de um passo (Clearfil S3 Bond / CS3B) e de um outro adesivo autocondicionante de dois passos (Clearfil Liner Bond F / CLBF) aplicado na dentina, antes de sua polimerização, na resistência ao cisalhamento. Material e métodos: Quarenta pré-molares hígidos foram seccionados vestibularmente para obtenção de superfícies dentinárias planas. Os espécimes foram divididos em 4 grupos (n = 10): Grupo (OS) - polimerização de CS3B +. Grupo (OS-L) - laser + CS3 + polimerização. Grupo (TS) - CLBF (apenas agente de adesão) + polimerização. Grupo (TS-L) - CLBF (somente agente de adesão) + laser + polimerização. O laser de diodo foi irradiado através de uma ponta de branqueamento de 8 mm durante 10 segundos (0,4 W, 10 Hz, 4 J). Todas as amostras foram cimentadas a blocos de compósitos, submetidos a 4.000 ciclos térmicos. As amostras foram testadas quanto à resistência ao cisalhamento em uma máquina universal de ensaios. Os dados obtidos foram analisados utilizandose Two-way (ANOVA) (p < 0,05) e o teste post-hoc de Bonferroni. Amostras representativas de cada grupo foram analisadas por microscopia eletrônica de varredura (MEV). Resultados: O grupo TS-L - (7,43 MPa) apresentou resistência ao cisalhamento estatisticamente significativa maior em relação ao grupo TS (5,13 MPa). Não houve diferença estatisticamente significativa entre o grupo OS-L - (6,49 MPa) e grupo OS - (7,28 MPa). O grupo TS-L exibiu a maior penetração de resina além da camada híbrida em MEV. Conclusões: A irradiação com laser de diodo de um agente adesivo colocado sobre a dentina sem o uso prévio de primers aumentou a força de adesão à dentina e é promissora como um novo protocolo de adesão dentinária. (AU)


Subject(s)
Dentin-Bonding Agents , Dentin , Lasers
4.
Natal; s.n; 2019. 61 p. tab, ilus, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-1537391

ABSTRACT

Este estudo teve por finalidade avaliar a influência dos cimentos endodônticos com um protocolo de irrigação na resistência de união sobre a estrutura dentinária das paredes da câmara pulpar de dentes bovinos restaurados imediatamente e após 7 dias do tratamento endodôntico. Foram avaliados os cimentos endodônticos: Cimento à base de resina epoxy (AH Plus ­ Dentsply, DeTrey, Konstanz- Alemanha) e Cimento de óxido de zinco e eugenol (Endofill ­ Dentsply Ind.com. LTDA ­ Brasil). Para a realização das restaurações foi utilizado o sistema adesivo Single Bond 2® (3M/ESPE) e a resina composta Z 350TM (3M/ESPE). 60 faces vestibulares da câmara pulpar de dentes bovinos foram distribuídos aleatoriamente em 4 grupos experimentais (G1-AHPlus Imediato; G2-AHPlus Mediato; G3-OZE Imediato; G4-OZE Mediato) e 2 controles (G5- NaOCl + EDTA Imediato e G6-NaOCl + EDTA Mediato). O protocolo de irrigação endodôntica deu-se através da imersão dos espécimes em solução de hipoclorito de sódio a 2.5% por 30 minutos e em EDTA 17% por 3 minutos. Os cimentos testados estiveram em contato com a parede dentinária pelo tempo de presa inicial, seguido de limpeza com algodão embebido em álcool 70% por 1 minuto. Os grupos experimentais de restauração mediata foram mantidos em estufa a 37ºC por 7 dias. Após o corte e a obtenção dos palitos de +/-1,0 mm² foi aplicado o teste de microtração na Máquina de Ensaios Universal e, em seguida, observados em microscópio óptico para classificação da fratura. Os valores da resistência de união foram submetidos ao teste não-paramétrico Wilcoxon-Mann-Whitney comparando dois a dois grupos a um nível de significância de 5%. Os resultados mostraram que o grupo G5 obteve menor valor de resistência de união, com diferença estatisticamente significativa (p<0,05) para os demais. O padrão de fratura mais observado nos grupos foi a coesiva em camada híbrida. Conclui-se que a associação NaOCl + EDTA diminui a resistência de união nas restaurações imediatas e que os cimentos endodônticos não alteraram a resistência de união nos períodos testados (AU).


This study aimed to evaluate the influence of endodontic sealer with an irrigation protocol on the bond strength on the dentinal structure of the pulp chamber walls of bovine teeth restored immediately and after 7 days of endodontic treatment. Endodontic sealer were evaluated: epoxy resin-based sealer (AH Plus - Dentsply, DeTrey, Konstanz- Germany) and zinc oxide and eugenol sealer (Endofill - Dentsply Ind.com. LTDA - Brazil). To perform the restorations, the Single Bond 2® adhesive system (3M / ESPE) and the composite resin Z 350TM (3M / ESPE) were used. 60 vestibular faces of the pulp chamber of bovine teeth were randomly assigned to 4 experimental groups (G1-AHPlus Immediate; G2-AHPlus Mediato; G3-OZE Immediate; G4-OZE Mediato) and 2 controls (G5- NaOCl + EDTA Immediate and G6- NaOCl + EDTA Mediato). The endodontic irrigation protocol was carried out by immersing the specimens in 2.5% sodium hypochlorite solution for 30 minutes and in 17% EDTA for 3 minutes. The tested sealers were in contact with the dentin wall for the initial setting time, followed by cleaning with cotton soaked in 70% alcohol for 1 minute. The experimental groups of mediated restoration were kept in an oven at 37ºC for 7 days. After cutting and obtaining the +/- 1.0 mm² toothpicks, the microtensile test was applied to the Universal Testing Machine and then observed under an optical microscope to classify the fracture. The bond strength values were subjected to the non-parametric Wilcoxon-Mann-Whitney test comparing two to two groups at a significance level of 5%. The results showed that the G5 group had a lower bond strength value, with a statistically significant difference (p <0.05) for the others. The most observed fracture pattern in the groups was cohesive in a hybrid layer. It is concluded that the association NaOCl + EDTA decreases the bond strength in immediate restorations and that endodontic sealer did not change the bond strength in the tested periods (AU).


Subject(s)
Humans , Root Canal Obturation , Root Canal Preparation , Retreatment , Dental Pulp Cavity , Zinc Oxide-Eugenol Cement/chemistry , Analysis of Variance , Statistics, Nonparametric , Radiography, Dental, Digital/instrumentation , Molar
5.
São José dos Campos; s.n; 2018. 73 p. il., tab., graf..
Thesis in Portuguese | BBO, LILACS | ID: biblio-1016217

ABSTRACT

O objetivo desta pesquisa foi avaliar a influência da utilização ou não do bond do sistema adesivo Adper Scotchbond Multiuso(A) e o bond Gluma da Heraeus(G) na resistência de união entre as resinas do tipo flow Filtek Bulk Fill Flow(F) e X-tra base (X) como base e uma convencional nanoparticulada Z350 XT(Z)) como cobertura. Simulando assim seu uso em reparos de restaurações diretas em dentes posteriores. Foram confeccionados 120 espécimes em resina composta do tipo flow no formato tronco-cônico com as dimensões de 2mm base menor, 4mm de altura e 4 mm de base maior. 60 Filtek Bulk Fill(F) e 60 Xtra base (X). Metade de cada grupo (n=30) foi envelhecida por termociclagem 5.000 ciclos de 5°C a 55°C, (FE, XE), a outra metade não sofreu envelhecimento (FN e XN). Esses espécimes foram divididos em 3 subgrupos (n=10), sobre a base menor dessas 10 amostras foi aplicado o Bond de cada sistema adesivo após condicionadas pelos seus respectivos ácidos nos tempos preconizados pelos fabricantes. As outras 10 unidades de cada grupo não receberam qualquer sistema adesivo. Na simulação do reparo as duas primeiras metades em teflon foram invertidas ficando a área menor voltada pra cima. Sobre essa face foram colocadas outras duas metades em teflon com a área menor voltada para baixo. Foi inserida então a resina Z350 pela técnica incremental e fotopolimerizada por 20s a 800mw/cm². Após 24h de armazenamento em água destilada, em estufa bacteriológica os espécimes, agora com formato de ampulheta, foram tracionados na máquina de ensaios universais (EMIC). Todos os espécimes fraturados tiveram o tipo de falha analisados ao estereomicroscópio e também ao microscópio eletrônico de varredura (MEV). Os dados coletados no ensaio de tração foram analisados através de ANOVA 3- fatores e teste de Tukey (p<5%). Houve diferença significativa (p<5%) para a variável aplicação de sistema adesivo para a resina Filtek Bulk Fill flow que apresentou médias maiores (24,99 ± 4,3 MPa) quando comparadas ao grupo no qual não foi aplicado adesivo (18,20 ± 5,31 MPa). O mesmo não ocorreu com a resina X-tra base, na qual o fator adesivo não interferiu significantemente. Quando comparado o desempenho das resinas Filtek Bulk Fill flow e X-tra base (26,99 ± 6,11 MPa) sem aplicação de sistema adesivo, também se verificou diferença significativa, o que não ocorreu para a resina X-tra base quando comparados ambos os subgrupos. As falhas foram 100% adesivas para todos os grupos(AU)


The aim of our paper was to analyse the bonding influence of Adper Scotchbond Multipurpose Adhesive (A) and Heraeus Gluma universal bond (G), or no bond application, on bond strength between microhibrid Filtek Bulk Fill Flow (F) and nanohibrid X-tra base (X) as based composite resin and the conventional nanoparticulate Z350 XT (Z)) as cover. Simulating non-invasive repairs of direct restorations on posterior teeth. A total of 120 specimens were made from flow composite resin in the conical trunk format with the dimensions of 2x4x4, for 40s with Led-5 (N/S LD51803005) at 800mw/cm². Sixty Filtek bulk fill (F) and sixty X-tra base (X) were made. Half of each group (n=30) was aged by thermocycling 5,000 cycles from 5° C to 55° C, (FE, XE), the other half were not subjected to any aging procedure (FN, XN). These specimens were randomly divided into 3 subgroups (n = 10), on the smaller diameter of the 10 samples the Bond of each adhesive system were applied after conditioned by their respectively acids at the time recommended by the manufacturers. The other 10 units of each group did not receive any adhesive system. In the sequency of repair simulation the first two Teflon halves were turned up with the smaller diameter turned upwards. Above this face were placed two other halves in Teflon with the smaller diameter facing down. The Z350 repair composite resin were inserted by incremental technique and photopolymerized for 20s at 800mw/cm². After 24h of storage in distilled water in a bacteriological oven, the now hourglass-shaped specimens were drawn in the universal testing machine EMIC. All the fractured specimens had the type of failure analyzed in stereomicroscope. The most significant faulting specimens were evaluated with electronic microscope (MEV). The data collected at the traction test were analyzed through 3-factor ANOVA and Tukey's test (p <5%). There was a significant difference (p <5%) for the variable adhesive system application for Filtek Bulk Fill flow resin that presented averages (24.99 ± 4.3 MPa) when compared to the group in which no adhesive was applied (18.20 ± 5.31 MPa). The same did not occur with X-tra base resin, in which the adhesive factor did not interfere significantly. When comparing the performance of Filtek Bulk Fill Flow resins and X-tra base (26.99 ± 6.11 MPa) without application of adhesive system, a significant difference was also observed, which did not occur for X-tra base resin when compared both subgroups. Most of the failures were adhesive for all groups. Scanning electron microscopy images do not reveal any traces of discontinuity between the layers of the materials used (resin x resin or resin x adhesive)(AU)


Subject(s)
Humans , Dental Cements/analysis , Tensile Strength , Composite Resins/administration & dosage
6.
Braz. dent. sci ; 20(1): 99-109, 2017. ilus, graf, tab
Article in English | LILACS, BBO | ID: biblio-836796

ABSTRACT

Objetivo: Avaliar o efeito da associação de tratamentos de superfície e agentes de união na resistência adesiva de reparos em resinas compostas. Materiais e Métodos: Cento e vinte espécimes de resina composta microhíbrida (Filtek Z250) envelhecidas em água destilada a 37 ºC por 6 meses foram submetidas a diferentes tratamentos de superfície antes do procedimento de reparo. Dez espécimes foram divididos aleatoriamente em 12 grupos: não tratados / sem agente de união (controle negativo); jateamento/sem agente de união; silano /sem agente de união; não tratado / adesivo de condicionamento ácido total; não tratado/ adesivo autocondicionante 1 passo; Não-tratado/adesivo autocondicionante 2 passos; Jateamento / adesivo de condicionamento ácido total; Jateamento / adesivo autocondicionante 1 passo; Jateamento / adesivo autocondicionante 2 passos; silano / adesivo de condicionamento ácido total; silano / adesivo autocondicionante 1 passo; silano / adesivo autocondicionante 2 passos. A resistência adesiva do procedimento de reparo com resina composta foi mensurada pelo teste de microcisalhamento. Resultados: ANOVA a 2 fatores e o teste de Tukey (α = 0,05) demonstraram diferença estatística significante entre os tratamentos de superfície e os sistemas adesivos. Conclusão: Os tratamentos de superfície foram capazes de aumentar a eficácia do reparo em resina composta apesar do agente de união utilizado em superfícies não tratadas. Os agentes de união autocondicionantes foram mais eficazes nos procedimentos de reparo quando não foi realizado tratamento de superfície. (AU)


Objective: The objective of this study was to evaluate the effect of combination of surface treatments and bonding agents on bond strength of repairs on aged composite resin. Materials and Methods: One hundred twenty microhybrid composite samples (Filtek Z250) aged in distilled at 37 ºC water for six months were submitted to different surface treatment prior to resin repairs. Ten specimens were randomly divided into 12 groups: non-treated/no bonding agent (negative control), sandblasting /no bonding agent, silane/ no bonding agent, non-treated/ etch-and-rinse; non-treated/one-step self-etch; non-treated/ two-step self-etch; sandblasting/etch-and-rinse; sandblasting/one-step self-etch; sandblasting/ two-step self-etch; silane coupling agent/etch-andrinse; silane coupling agent/ one-step self-etch; silane coupling agent/two-step self-etch. Micro shear testing was performed to bond strength assessment. Results: Two-way ANOVA and Tukey's test (α = 0.05) demonstrated significant difference between the surface treatments and adhesive systems. Only no treated surface/etchand-rinse group showed lower bond strength values when compared to other groups. Conclusion: The surface treatments were capable to increase the effectiveness of the repair in composite resin despite bonding agent used in untreated surfaces. The self-etching bonding agents were more effective on bonding to repair procedures when no surface treatment was performed. (AU)


Subject(s)
Composite Resins
7.
Bauru; s.n; 2017. 143 p. tab, ilus, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-880165

ABSTRACT

A adição de corantes fluorescentes a adesivos odontológicos possibilita a investigação da distribuição espacial desses materiais na interface dente-restauração, utilizando-se a microscopia confocal de varredura a laser (MCVL). A literatura indica falta de padronização na aplicação de agentes fluorescentes com tal finalidade. Esse estudo sistematizou estratégias para a adição de rodamina B (RB) e fluoresceína sódica (FS) a um sistema adesivo convencional de três passos, Adper Scotchbond Multi-Purpose (MP), e um autocondicionante de dois passos, Clearfil SE Bond (SE), considerados "padrão-ouro" na Odontologia. Os objetivos principais foram (a) determinar a menor faixa de concentrações de RB e FS necessária para produzir imagens satisfatórias da interface dentina-adesivo e (b) avaliar o efeito da adição desses corantes sobre algumas propriedades das resinas. Os adesivos foram marcados com RB ou FS em concentrações decrescentes (0,5, 0,1, 0,02 e 0,004 mg/mL) por meio de um método de dispersão semidireto. O comportamento fotofísico/ fluorescente dos adesivos marcados foi investigado por espectroscopia de fotoluminescência e MCVL. Paralelamente, avaliaram-se os adesivos quanto ao grau de conversão (GC) e ao ângulo de contato (AC). Tanto os resultados de GC como os de AC foram submetidos à análise de variância com dois fatores (adesivo e tratamento) com α = 0,05, seguida de teste post-hoc de Tukey. Os máximos comprimentos de onda de emissão e de excitação da RB e da FS foram influenciados pelo meio polimérico e pela concentração de corante de modo geral. A MCVL preliminar de amostras de adesivo polimerizado, realizada sob condições experimentais padronizadas, mostrou que o comportamento fluorescente da RB em MP e SE foi muito semelhante na mesma concentração de corante, mas o mesmo não pôde ser dito do comportamento da FS, que foi notavelmente inferior no adesivo autocondicionante, SE, na concentração mais alta. Em dentina, os adesivos preparados com RB nas concentrações-alvo de 0,1 e 0,02 mg/mL apresentaram fluorescência ótima; já aqueles preparados com 0,004 mg/mL produziram fraco sinal. Adesivos preparados com FS a 0,5 mg/mL apresentaram ótima fluorescência na interface de adesão, enquanto que concentração menor desse corante não produziu sinal suficiente. Padrões morfológicos aparentemente atípicos foram observados na interface de adesão, quando da associação do adesivo SE com o corante FS. A adição de RB e FS nas quatro concentrações indicadas aos adesivos MP e SE não afetou o GC nem o AC em comparação com os grupos de controle correspondentes. Em suma, a RB mostra-se um corante mais versátil que a FS na avaliação morfológica das interfaces dentina-MP e dentina-SE via MCVL. A menor faixa de concentrações de RB nos adesivos MP e SE, na qual é possível produzir imagens satisfatórias das interfaces, situa-se entre 0,1­0,02 mg/mL. Já o corante FS deve ser adicionado a esses adesivos a pelo menos 0,5 mg/mL para produzir níveis de fluorescência satisfatórios na interface de adesão. A não ocorrência de efeitos deletérios sobre a polimerização e a molhabilidade das resinas estabelece uma margem de segurança para a incorporação desses agentes fluorescentes (em concentração ≤ 0,5 mg/mL) nesses sistemas monoméricos.(AU)


The addition of fluorescent dyes to dental adhesives makes it possible to investigate the spatial distribution of such resin-based materials in the tooth-restoration interface, using confocal laser scanning microscopy (CLSM). Literature indicates a lack of standardization on the application of fluorescent agents for this purpose. This work presents strategies for adding rhodamine B (RB) and fluorescein sodium salt (FS) to a three-step etch-and-rinse adhesive system, Adper Scotchbond Multi-Purpose (MP), and a two-step self-etching one, Clearfil SE Bond (SE), both regarded as "gold standard" in restorative dentistry. The main objectives were (a) to determine the lowest range of RB and FS concentrations required to produce suitable images of the dentin-adhesive interface via CLSM and (b) to investigate potential effects of addition of these dyes on some resin properties. The adhesives were labeled with RB or FS at decreasing concentrations (0.5, 0.1, 0.02 and 0.004 mg/mL) by means of a semi-direct dispersion method. The photophysical/fluorescent behavior of the labeled resins was investigated by photoluminescence spectroscopy and by CLSM. The adhesives were also investigated with regards to the degree of conversion (DC) and contact angle (CA). A two-way ANOVA of "adhesive" and "treatment" was conducted on DC and CA separately, followed by Tukey's test. The maximum emission and excitation wavelengths of RB and FS were influenced by the host polymer and the dye concentration in general. The preliminary CLSM of cured adhesive samples, performed with standardized settings, showed that the fluorescent behavior of RB in MP and SE was very similar in the same dye concentration, unlike the behavior of FS, which was lower in the self-etching adhesive for the highest dye concentration. In dentin, the adhesives prepared with RB at the target concentrations of 0.1 and 0.02 mg/mL presented optimal fluorescence; those with 0.004 mg/mL produced poor signal. Adhesives prepared with FS at 0.5 mg/mL presented optimal fluorescence at the bonding interface, whereas lower concentrations of FS did not produce sufficient signal. Atypical morphological features were observed at the bonding interface, when adhesive SE was used with FS. The addition of RB and FS at the four decreasing concentrations to adhesives MP and SE did not affect DC or CA compared to the corresponding controls. In short, RB is more versatile than FS for the morphological characterization of dentin-MP and dentin-SE interfaces via MCVL. The lowest range of RB concentrations in adhesives MP and SE that can produce suitable images of the bonding interface lies between 0.1­0.02 mg/mL. The dye FS should be added to these adhesives at 0.5 mg/mL at least to produce satisfactory fluorescence levels at the bonding interface. Since negative effects on polymerization and wettability of the resins were not observed, the use of RB and FS (in concentration ≤ 0.5 mg/mL) together with MP and SE should be reliable in terms of resin properties.(AU)


Subject(s)
Fluorescein/chemistry , Fluorescent Dyes/chemistry , Resin Cements/chemistry , Rhodamines/chemistry , Analysis of Variance , Ethanol/chemistry , Microscopy, Confocal , Reference Values , Reproducibility of Results , Self-Curing of Dental Resins/methods , Spectrometry, Fluorescence , Spectrophotometry, Infrared
8.
Braz. dent. sci ; 19(2): 104-110, 2016. tab
Article in English | LILACS | ID: lil-788625

ABSTRACT

This study evaluated the microtensile bond strength of a universal adhesive system applied to deep dentin under different bonding strategies.Material and Methods: Fifteen human third molar shad the coronal portion removed exposing deep dentin and were assigned into 3 groups according to the adhesive system: G1(control): 2-steps totaletch(Adper Single Bond 2, 3M ESPE); G2: 1-stepself-etch universal adhesive (Scotchbond Universal,3M ESPE); G3:2 steps total-etch universal adhesive(Scotchbond Universal, 3M ESPE). Composite build up swere performed on the dentin surfaces and after water storage for 24 h, teeth were sectioned to obtain40 bonded beams per group with sectional areaof 0.9 mm2. The specimens were submitted to the microtensile bond strength (μTBS) test until failure.Statistical analyses were computed using one-wayANOVA (p = 0.05). Results: The mean μTBS (inMPa) were G1 = 22.27, G2 = 22.85 and G3 = 20.3.After statistical analysis, no significant differences were observed among the groups. Conclusions:Universal adhesive system performed similarly tothe total-etch adhesive and was not affected by theadhesion strategy...


O estudo avaliou a resistência de união à microtração de um sistema adesivo universal aplicado em dentina profunda sob diferentes estratégias adesivas. Material e Métodos: 15 terceiros molares tiveram a porção coronária removida,expondo dentina profunda, sendo então divididos em 3 grupos de acordo com o sistema adesivo: G1 (controle) sistema adesivo convencional de 2 passos e condicionamento ácido total (Adper SingleBond 2, 3M ESPE); G2: sistema adesivo universal,1 passo, autocondicionante (Scotchbond Universal,3M ESPE); G3: sistema adesivo universal, 2 passos e condicionamento ácido total (Scotchbond Universal,3M ESPE). As porções coronárias foram reconstruídas em resina composta e após 24 h em água destilada os espécimes foram seccionados para obtenção de 40 filetes por grupo. Os filetes foram submetidos ao teste de microtração à velocidade de 0,5 mm/min e os dados analisados estatisticamente. Results:Não foram observadas diferenças estatísticas entre os grupos, sendo as médias de resistência de união(MPa): G1 = 22,27, G2 = 22,85 and G3 = 20,3.Conclusão: O sistema adesivo universal apresentou performance similar ao sistema adesivo convencional e seu desempenho não foi afetado pela estratégia adesiva utilizada...


Subject(s)
Humans , Dentin , Dentin-Bonding Agents , Tensile Strength
9.
Braz. dent. sci ; 18(4): 59-67, 2015. tab
Article in English | LILACS | ID: lil-786311

ABSTRACT

This study evaluated the hardness and modulus of elasticity of the dentin bond interface using total-etch(Single Bond /SB) and self-etch (Clearfil SE Bond/CSEB) adhesives associated with Nd:YAG Laser irradiation through the unpolymerized adhesives. Material and Methods: The occlusal surfaces of 12 human third molars were ground until superficial dentin was exposed. A standardized circular cavity was performed on the occlusal surface. Specimens were sectioned in the mesio-distal direction, and the 24 hemi-crowns were divided into four groups: Group SB/Control - SB + polymerization; GroupSB/Laser - SB + Nd:YAG laser (174.16J/cm2/60s/noncontact)+ polymerization; Group CSEB/Control – CSEB +polymerization; Group CSEB/Laser - CSEB + Nd:YAG laser(174.16J/cm2/cm2/60s/non-contact) + polymerization. Composite were placed in the cavities and polymerized. The specimens were immersed in distilled water and stored in an oven at 37ºC for 24h and then submitted to nanoindentation in a Nano Indenter® XP appliance. Results: The results were submitted to ANOVA, Tukey’stest and Student’s-t test (p < 0.05). Conclusion: It was concluded that the application of the Nd:YAG laser inboth adhesive systems did not changed the hybrid layer hardness; however, it increases the modulus of elasticityin the hybrid layer for both adhesives tested and it may bepreserves the integrity of the adhesive interface and its durability. Clinical relevance: The application of Nd:YA Glaser prior to photopolymerization of adhesive systems can increase the modulus of elasticity in the hybrid layerand may contribute to stress distribution in the adhesive interface during the polymerization preserving the integrity of the adhesive interface and its durability...


este estudo avaliou a dureza e o módulo de elasticidade da interface adesiva a dentina usando adesivo convencional (Sinngle Bond /SB) e adesivo autocondicionante (Clearfil SE Bond/CSEB) associados com irradiação do Laser Nd:YAH sobre os adesivos não polimerizados. Material e Métodos: As superfícies oclusais de 12 terceiros molares humanos foram desgastadas ate exposição de dentina superficial plana. Cavidades circulares padronizadas foram realizadas na superficie oclusal. Os espécimes foram seccionados no sentido mesio-distal, e as 24 hemicoroas foram divididas em quatro grupos: Grupo SB/Controle - SB + fotopolimerização; Grupo SB/Laser- SB + Laser Nd:YAG (174,16J/cm2/60s/não-contato)+ fotopolimerização; Grupo CSEB/Controle – CSEB +fotopolimerização; Grupo CSEB/Laser - CSEB + LaserNd:YAG (174.16J/cm2/cm2/60s/ não-contato) +fotopolimerização. Restaurações de resina composta foram realizadas nas cavidades e fotopolimerizadas. Os espécimes foram armazenados em água destilada a 37 ºC por 24 h e submetidas a nanoindentação no aparelho Nano Indenter® XP. Resultados: Os resultados foram submetidos ao ANOVA, seguidos dos testes de Tukey e T-Student (p < 0,05). Conclusão:Foi concluído que a aplicação do Laser de Nd:YAG nos adesivos não alterou a dureza da camada híbrida;entretanto, aumentou o módulo de elasticidade de ambos os adesivos testados e talvez preserve a integridade da interface adesiva e sua durabilidade...


Subject(s)
Humans , Dental Cements , Dentin , Dental Materials , Lasers, Solid-State
10.
Rev. bras. odontol ; 71(2): 163-169, Jul.-Dez. 2014. ilus, graf
Article in Portuguese | LILACS | ID: lil-766106

ABSTRACT

O objetivo deste estudo foi avaliar a resistência à microtração de sistemas adesivos em função da presença ou não da camada de colágeno e do tempo de armazenamento. Para tanto foram utilizados 24 terceiros molares restaurados utilizando-se diferentes sistemas adesivos, com ou sem tratamento prévio com NaOCl, e armazenados por 24 horas e 12 meses. Os valores de resistência foram submetidos à análise estatística. O tratamento prévio com NaOCl não foi significativo em 24 horas. Entretanto, este tratamento manteve resultados satisfatórios de adesão após 12 meses para todos os sistemas adesivos, com exceção apenas do Prime & Bond NT.


The aim of the present study was to evaluate the microtensile bond strength of different bond systems due to presence or absence of the collagen layer and storage time. Therefore, 24 third molars were restored using different bond systems, with or without pretreatment with NaOCl, and stored for 24 hours and 12 months. The microtensile strength values were subjected to statistical analysis. The pretreatment with NaOCl was not significant in 24 hours. However, this pretreatment remained satisfactory bond results after 12 months for all bond systems, except for Prime & Bond NT.


Subject(s)
Dentin-Bonding Agents , Enamel Microabrasion , Materials Science
11.
Full dent. sci ; 5(20): 641-646, jul.-set. 2014. ilus, graf
Article in Portuguese | LILACS, BBO | ID: lil-737456

ABSTRACT

Os adesivos dentários são combinações de monômeros resinosos hidrofílicos e hidrofó- bicos, de diferentes pesos moleculares e solventes, que estabelecem ligação entre o material restaurador e a estrutura dentária após polimerização. Sistemas adesivos atuais são indicados para diversas aplicações odontológicas e classificados como condicionamento total (etch-and- -rinse) ou autocondicionamento (self-etching) e sua intenção de uso difere no número de etapas de aplicação e como eles interagem com as estruturas dentais naturais.


Dentin adhesives are combinations of hydrophilic and hydrophobic monomers, with different molecular weights and solvents that connect the restorative material to the tooth structure after polymerization. Current adhesive systems are suitable for various dental applications and classified as etch-and-rinse or self-etching. The purpose of their use differs according to the number of application steps and how they interact with the natural dental structures.


Subject(s)
Dental Cements/classification , Chlorhexidine/therapeutic use , Dental Enamel , Tensile Strength
12.
Braz. dent. sci ; 16(1): 73-79, 2013. tab, ilus
Article in English | LILACS, BBO | ID: lil-698281

ABSTRACT

Objective: The aim of this study was to compare the bond strength of two self-etching adhesive systems with different types of dentin abrasion. Methods: Thirty two sound human molars were selected and had the dentin surface exposed and flattened. Tooth were randomly divided into four experimental conditions, according with the adhesive system [Clearfil SE Bond (SE) and One-Up Bond F(ONE)] and the type of dentin abrasion [conventional diamond bur (D) and ultrasound diamond bur (CVD)]. The adhesives were applied following manufactures’ instructions and light cured composite blocks of 4mm height were placed over dentin. After storage in distilled water for 24 h in 37 ºC, serial cuts were made on mesio-distal and buccal-lingual direction, obtaining specimens with stick format, with cross section of 8mm². The microtensile test was performed at a crosshead speed of 0.5 mm/min and load cell of 10kg, until failure. Data were submitted to ANOVA-2-Way followed by Tukey test (5%). Results: The results (MPa) were: D/ SE: 24.06 ± 8.84, D/ONE:15.03 ± 8.61, CVD/SE: 39.90 ± 8.24 and CVD/ONE:15.03 ±8.61. It can be concluded that the adhesive system Clearfil SE Bond showed higher bond strength related with the abrasion with CVD; the type of dentin abrasion interfered on the performance of Clearfil SE Bond but did not influence the One-Up Bond F results


Objetivo: O objetivo desta pesquisa foi comparar a resistência de união de dois sistemas adesivos autocondicionantes com diferentes métodos de preparo da dentina. Métodos: Foram utilizados 32 molares humanos hígidos extraídos, sendo que a superfície dentinária oclusal foi exposta e planificada. Os dentes foram aleatoriamente divididos em quatro diferentes condições experimentais de acordo com o sistema adesivo: Clearfil SE Bond (SE) ou One- Up Bond F (ONE) e com o método de preparo da dentina: ponta diamantada em alta rotação (D) ou ponta diamantada em ultra-som (CVD). Os adesivos foram aplicados de acordo com as recomendações do fabricante e foram confeccionados blocos de 5mm de altura de resina composta fotopolimerizável, pela técnica incremental. Após estocagem em água destilada por 24 h a 37 ºC, foram realizadas secções seriadas no sentido mésio-distal e vestíbulo-lingual, obtendo-se espécimes em forma de palitos, com secção transversal de aproximadamente 0.8 mm2. Os corpos-de-prova foram submetidos ao ensaio de microtração com velocidade de 0.5mm/min e célula de carga de 10kg. Os dados foram submetidos à análise estatística ANOVA e teste de Tukey (5%). Resultados: Os resultados (MPa) foram: D/SE: 24,06 ± 8,84, D/ONE: 15,03 ± 8,61, CVD/SE: 39,90 ± 8,24 e CVD/ONE:15,03 ± 8,61. Concluiu-se que o sistema adesivo Clearfil SE Bond apresentou superioridade significativa de resistência de união em relação ao preparo com ponta CVD; o método de preparo da dentina interferiu no desempenho do Clearfil SE Bond e não influenciou o desempenho do One-Up Bond F


Subject(s)
Humans , Dentin , Dentin-Bonding Agents , Tensile Strength
13.
Full dent. sci ; 3(11): 316-325, abr.-jun. 2012. ilus
Article in Portuguese | LILACS, BBO | ID: lil-681662

ABSTRACT

Na técnica convencional de cimentação em prótese fixa, o adesivo é aplicado e/ou fotopolimerizado somente na fase de cimentação da peça. Caso a dentina seja contaminada anteriormente, esta adesão é prejudicada. A dentina recém-preparada é considerada o substrato ideal para a adesão, pois não há risco de contaminação. Com base nessa ideia, tem sido sugerido que logo após o preparo e antes da moldagem, o mesmo seja selado com um adesivo dentinário. Esta técnica é denominada Selamento Imediato da Dentina (SID) e possui várias vantagens em relação à técnica convencional de cimentação. O objetivo deste trabalho é descrever e discutir esta técnica de aplicação clínica que contribui para o aumento da resistência e ajuda a evitar a sensibilidade dentária


In indirect restorations conventional luting, the adhesive is applied and/or light cured during the luting procedure, after provisional phase. If dentin is infected previously, this adhesion is impaired. The freshly cut dentin is considered the ideal substrate for dentin bonding, because there is no risk of contamination. Based on this idea, it has been suggested that after exposing dentin, it must be sealed with a dentin adhesive. This technique is called Immediate Dentin Sealing (IDS) and has several advantages over the conventional luting. The aim of this study is describe and discuss this clinical technique that contributes to increase dentin bond strength and prevents tooth sensitivity


Subject(s)
Dental Caries/diagnosis , Dental Caries , Dental Cements/therapeutic use , Dentin/pathology , Dental Leakage/diagnosis , Dental Leakage/etiology , Dental Leakage , Dentin Sensitivity/diagnosis , Dentin Sensitivity/etiology
14.
Braz. dent. sci ; 15(2): 56-62, 2012. ilus, tab
Article in English | LILACS, BBO | ID: lil-681470

ABSTRACT

The aim of this study was to compare the bond strength to three different depths of remaining human and bovine dentin, through shear bond strength test, and to establish a possible relationship among the depths of the substrates to contribute for the replacement of human dentin in bond strength tests. Forty-eight human teeth (H) and forty-eight bovine teeth (B), freshly extracted, stored in distilled water and frozen at -18 ° C for at most four weeks were used in this study. 240-, 400-, 600- and 800-grit sandpapers were used to expose the dentin and standardize the smear layer at 0.5, 1.0 and 2.0mm of dentin thickness. Scotchbond Multi-Purpose Plus adhesive system was used following the manufacturer’s instructions, on a standardized area of 4mm, followed by the incrementally application of Z100 resin composite (3M). The shear bond test was performed in the Instron Universal machine at cross-head speed of 0.5mm/min. Statistical analysis was performed by ANOVA (p <0.05). There were significant differences in bond strength between H and B teeth, with the highest values for H teeth. There was a significant difference in bond strength to the depths analyzed but there was similarity in behavior between H (0.5mm) and B (2mm) substrates. Bovine substrate can be used for laboratory studies of bond strength as indicative of the initial performance of new products, although the differences related to human substrate should be observed.


O objetivo do presente estudo foi comparar a resistência adesiva da dentina humana e bovina em três diferentes espessuras de remanescente, frente ao teste de cisalhamento, a fim de estabelecer uma possível relação de profundidade entre os substratos visando contribuir para a substituição da dentina humana em testes de adesão. Empregaram-se 48 dentes humanos (H) e 48 dentes bovinos (B), recém-extraídos, armazenados em água destilada e congelados a –18°C, por no máximo quatro semanas. Foram utilizadas lixas de granulação 240, 400, 600 e 800, para expor a dentina e padronizar a smear layer, com espessura de dentina de 0,5, 1,0 e 2,0mm. O sistema adesivo Scotchbond Multi-Uso Plus foi utilizado seguindo instruções do fabricante, em uma área padronizada de 4mm, seguido da aplicação incremental da resina Z100 (3M). O ensaio de cisalhamento foi realizado em máquina Instron Universal à velocidade de 0,5mm/min. Foi realizada análise estatística pelo teste ANOVA a dois critérios (p < 0,05). Houve diferença significativa entre a resistência adesiva em dentes H e B, sendo os maiores valores para H; houve diferença significativa de resistência para as profundidades analisadas; houve semelhança de comportamento entre os substratos H 0,5mm e B 2mm. O substrato B pode ser empregado em estudos laboratoriais de resistência adesiva como indicativos da performance inicial de novos produtos, observando-se as diferenças existentes entre eles.


Subject(s)
Animals , Cattle , Dentin , Shear Strength
15.
Rev. odontol. UNESP (Online) ; 40(3): 113-117, maio-jun. 2011. tab
Article in Portuguese | LILACS, BBO | ID: lil-614436

ABSTRACT

Introdução: Sabe-se que sistemas adesivos autocondicionantes podem atuar como membranas semipermeáveis, o que pode comprometer a adesão. Objetivo: Buscou-se avaliar os efeitos da aplicação adicional de resina hidrofóbica sobre a resistência de união à microtração de sistemas adesivos autocondicionantes de frasco único sobre dentinabovina. Material e método: Sessenta incisivos bovinos tiveram a face vestibular desgastada até se obter superfície dentinária plana. Foram utilizados os seguintes sistemas adesivos: Clearfil Tri S Bond (CTSB), AdheSE One (ADO) e One Coat 7.0 (OC). Os sistemas adesivos foram testados com (G4, G5, G6) e sem (G1, G2, G3) a aplicação de camada adicional de material hidrofóbico do mesmo fabricante (Clearfil SE Bond, AdheSE e One Coat SE, respectivamente), resultando em seis grupos experimentais (n = 10). Após o procedimento adesivo, resinacomposta Z-350 foi inserida em três incrementos de 1 mm. Todo o procedimento adesivo restaurador foi executado sob pressão pulpar simulada e o teste de microtração foi executado imediatamente após a polimerização da resina composta. Os dados obtidos foram submetidos à ANOVA e ao teste de Tukey (p < 0,05). Resultado: Para todos os adesivos testados, os piores resultados foram observados nos grupos em que a camada adicional de resina hidrofóbica não foi aplicada. Conclusão: A aplicação de camada adicional de material hidrofóbico pode melhorar a resistência de união de sistemas adesivos autocondicionantes de passo único.


Introduction: It is known that self-etching adhesive systems can act as semi-permeable membranes. Objective: Evaluate the effects of additional layer of hydrophobic resin on the microtensile bond strength of self-etching one-bottle adhesives. Material and method: Sixty bovine incisors were used in this study. The facial enamel surfaces of the crowns were abraded with silicon carbide paper to expose flat, mid-coronal dentin surfaces. The following adhesives were used: Clearfil Tri S Bond (CTSB), AdheSE One (ADH) and One Coat 7.0 (OC). Each material was tested with and without applying an additional layer of hydrophobic material from the same manufacturer. Z-350 composite resin was inserted in three 1 mm increments. All adhesive restorative procedure was performed under simulated pulpal pressure and the microtensile test was performed immediately after curing the compositeresin. Data were submitted to ANOVA and Tukey test (p < 0.05). Result: For all adhesives tested, the worst results were observed in groups which the additional layer of hydrophobic resin was not applied. Conclusion: The application of additional layer of hydrophobic material can improve the adhesion of self-etching all-in-one adhesive systems.


Subject(s)
Animals , Cattle , Analysis of Variance , Composite Resins , Dental Cements , Shear Strength , Incisor
16.
Rev. dental press estét ; 7(4): 52-59, out.-dez. 2010. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-578149

ABSTRACT

Para analisar a capacidade de selamento marginal de três sistemas adesivos com diferentes formas de tratamentos superficiais, foram selecionados 45 incisivos bovinos, íntegros e recém-extraídos. Cada dente recebeu um preparo cavitário Classe V no limite cemento-esmalte. Os preparos foram padronizados nas seguintes dimensões: 1,5mm de profundidade e 2,0mm de diâmetro. A margem incisal foi deixada em esmalte e a margem gengival localizada abaixo da junção cemento-esmalte. Os dentes foram divididos em três grupos com 15 dentes cada. No grupo I foi utilizado o Adesivo XP Bond com dentina deixada úmida após condicionamento ácido. O grupo II também teve aplicação do Adesivo XP Bond, sendo que a dentina foi seca após condicionamento ácido. No grupo III o sistema utilizado foi o Adper Single-Bond 2. Todos os dentes foram restaurados com resina composta nanoparticulada Filtek - Z350 (3M). Em seguida foi realizada a ciclagem térmica em 300 ciclos, e os dentes foram imersos em solução aquosa de azul de metileno 2% por um período de 3 horas. Para avaliação do grau de penetração do corante, foram determinados escores de 0 a 3. A análise da penetração do corante foi realizada e o teste Kruskal-Wallis ao nível de significância de 5% foi aplicado. Em esmalte e em dentina houve diferença entre os grupos, porém a infiltração foi maior na dentina do que no esmalte.


Subject(s)
Animals , Composite Resins , Dental Enamel , Dentin , Dental Cementum
17.
Acta odontol. latinoam ; 23(2): 111-116, Sept. 2010. ilus, graf, tab
Article in English | LILACS | ID: biblio-949647

ABSTRACT

The aim of this study was to evaluate by micro-shear bond strength test, the bond strength of composite resin restoration to enamel submitted to whitening dentifrices. Forty bovine teeth were embedded in polystyrene resin and polished. The specimens were randomly divided into eight groups (n= 5), according to the dentifrice (carbamide peroxide, hydrogen peroxide and conventional dentifrice) and the adhesive system (Prime & Bond 2.1 and Adper Single Bond 2). Dentifrice was applied for 15 minutes a day, for 21 days. Thirty minutes after the last exposure to dentifrice, the samples were submitted to a bonding procedure with the respective adhesive system. After that, four buttons of resin were bonded in each sample using transparent cylindrical molds. After 24 hours, the teeth were submitted to the micro-shear bond strength test and subsequent analysis of the fracture mode. Data were submitted to analysis of variance and Fisher's PLSD test (α=0.05). The micro-shear bond strength showed no difference between adhesives systems but a significant reduction was found between the control and carbamide groups (p=0.0145) and the control and hydrogen groups (p=0.0370). The evaluation of the failures modes showed that adhesive failures were predominant. Cohesive failures were predominant in group IV. The use of dentifrice with peroxides can decrease bonding strength in enamel.


O objetivo deste trabalho foi avaliar, pelo metodo de microcisalhamento, a resistencia adesiva obtida em restauracoes de resina composta realizadas sobre o esmalte dental previamente exposto a diferentes dentifricios. Para isso, quarenta dentes bovinos foram incluidos em resina de poliestireno e polidos. Os dentes foram divididos aleatoriamente em 8 grupos (n=5) de acordo com o dentifricio utilizado (cremes contendo peroxido de hidrogenio, peroxido de carbamida ou dentifricio convencional) e sistema adesivo (Prime & Bond 2.1 ou Adper single Bond 2). Os dentes foram expostos por 15 minutos por dia durante 21 dias as suspensoes dos respectivos cremes dentais. Trinta minutos apos a ultima exposicao ao dentifricio, os dentes foram restaurados empregando os 2 diferentes sistemas adesivos e resina composta. Apos 24 horas os dentes foram submetidos ao teste de microcisalhamento e posterior analise do padrao de fratura. Os resultados obtidos foram submetidos a analise de variancia e teste de Fisher's PLSD (α=0.05). Nao foi detectada diferenca estatistica entre os adesivos, porem entre os tratamentos com dentifricios, houve reducao estatisticamente significante entre os grupos controle x carbamida (p=0.0145) e entre o grupo controle x hidrogenio (p=0.0370). Na avaliacao do tipo de fratura houve predominancia de falhas adesivas, com excecao do grupo IV que apresentou maior fratura coesiva em esmalte. Assim, a utilizacao de cremes dentais, contendo peroxidos em suas formulacoes, pode provocar uma reducao na resistencia de uniao ao esmalte.


Subject(s)
Animals , Cattle , Acetone , Polymethacrylic Acids , Dental Bonding , Dental Cements , Dental Enamel/drug effects , Dentifrices , Tooth Bleaching Agents/pharmacology
18.
Odontol. clín.-cient ; 9(1): 77-81, jan.-mar. 2010. ilus
Article in Portuguese | LILACS, BBO | ID: lil-541612

ABSTRACT

Cresce a procura em consultórios odontológicos por procedimentos estéticos e que simplificam o tempo de atendimento. A odontologia adesiva tem sido aprimorada pelo desenvolvimento de várias técnicas e sistemas de cimentação adesiva para restaurações estéticas indiretas tipo inlay e onlay. Este artigo relata o caso clínico da paciente M.F. cujas restaurações em amálgama defeituosas dos elementos 24, 25 e 26 foram trocadas por restaurações indiretas tipo inlay, confeccionados indiretamente com a resina composta condensável P-60 (3M/ESPE). Foi utilizado como agente cimentante o Relyx Unicem (3M/ESPE), um material de cura dual e inovador, por se tratar de um cimento resinoso autocondicionante. A sequência técnica para preparo dos remanescentes dentários bem como para a confecção das peças protéticas e cimentação destas foram descritas. Observou-se que apesar de recentemente lançado no mercado, o cimento resinoso autocondicionante é de grande valia para o cirurgião-dentista, por permitir uma minimização do tempo clínico de atendimento quando da cimentação de restaurações indiretas em dentes posteriores.


The search for esthetic and fast procedures has been growing in dental offices. The adhesive dentistry has been improved for the development of several adhesive cementation techniques and systems for indirect restorations type inlay and onlay. This paper presents a petient M.F clinical report about the substitution of defective amalgam restorations in dental elements 24, 25 and 26 by indirect restorations type inlay, confectioned indirectly with P-60 (3M/ESPE) composite resin. The Relix Unicem (3M/ESPE) cement was used. It is an innovative and dual cure material, a self-etching resinous cement. The technique sequences to dental remainders preparation and to the prostheses confection and their cementation were described. It was observed that, although recently launched in the market, the resinous cement is important because it minimizes the clinical time of cementation indirect restorations in posterior teeth.


Subject(s)
Cementation , Resin Cements , Dental Materials
19.
Rev. odonto ciênc ; 25(2): 216-220, 2010. ilus
Article in English | LILACS, BBO | ID: lil-573173

ABSTRACT

Purpose: In this case report, the clinical performance of a microhybrid resin composite placed with or without a flowable resin composite was compared, over a 48-month period. Case description: The patient of this case report presented 2 pairs of equivalent cervical abfraction lesions, under occlusion. Four restorations were placed in teeth 34, 35, 44 and 45. The restorations were divided into groups (Single Bond + Filtek-Flow + Filtek Z250 or Single Bond + Filtek Z250) and the materials were applied according to the manufactures instructions. Two previously calibrated operators placed the restorations and two other independent examiners evaluated the restorations at baseline and after 48 months, according to the USPHS criteria and modified criteria for color match. Conclusion: After 48 months of evaluation the lesions restored with Filtek-Flow as a liner under Filtek Z250 did not show better clinical performance than the restorations without Filtek-Flow. All restorations showed a trend toward dark yellowing after 48 months.


Objetivo: Este relato de caso compara o desempenho clínico após 48 meses de restaurações de lesões cervicais não cariosas com uma resina composta microhíbrida associada ou não a uma camada de resina flow como um agente intermediário. Descrição do caso: O paciente do presente caso apresentava 2 pares de lesões cervicais não cariosas ocasionadas por abfração sob oclusão. Nos elementos dentários 35 e 44 as restaurações foram feitas com Single Bond + Filtek-Flow + Filtek Z250 e nos elementos 45 e 34 com Single Bond + Filtek Z250, sendo os materiais empregados de acordo com as recomendações do fabricante. Dois operadores previamente calibrados colocaram as restaurações e dois outros examinadores avaliaram as restaurações no período imediato (baseline) e após 48 meses, de acordo os critérios USPHS modificado para o critério cor. Conclusão: Após 48 meses as lesões restauradas com a resina flow como uma camada intermediária não demonstraram melhor desempenho clínico em relação às restaurações sem a resina flow. Todos os grupos apresentaram uma tendência à descoloração após 48 meses de acompanhamento clínico.


Subject(s)
Humans , Male , Middle Aged , Dental Cements/therapeutic use , Composite Resins/therapeutic use , Tooth Injuries/therapy
20.
RSBO (Impr.) ; 6(4): 375-380, dez. 2009.
Article in Portuguese | LILACS-Express | LILACS | ID: lil-533939

ABSTRACT

Introdução: Sistemas adesivos convencionais são caracterizados pelo condicionamento ácido da estrutura dental previamente à aplicação dos monômeros. Esses materiais podem ser classificados em 3 passos (quando primer e adesivo se encontram em frascos separados) ou 2 passos (em que a função de primer e adesivo é desempenhada por um único material). Objetivo: Verificar a influência do momento da inserção do material restaurador (inserção imediata ou tardia) sobre os valores de resistência de união de adesivos convencionais de 2 e 3 passos por meio do teste de microtração. Material e métodos: Foram utilizados dentes incisivos bovinos que tiveram sua superfície vestibular desgastada até se obter uma superfície plana em dentina. Empregaram-se sistemas adesivos convencionais de 3 passos (Scotchbond Multi-Uso ? SMP; Optibond FL ? OFL; Bond-It ? BIT) e de 2 passos (Single-Bond ? SB; Optibond Solo Plus ? OSP; Bond-1 ? B1), e resina composta (Z-350) foi aderida a esse substrato em dois diferentes momentos: imediata e tardiamente (após 24 horas). Todos os procedimentos foram realizados com simulação da pressão pulpar fisiológica. Os resultados foram submetidos à análise estatística Anova e ao teste de Tukey (p < 0,05). Resultados: Para inserção imediata da resina composta, todos os adesivos apresentaram comportamentos semelhantes. Os sistemas adesivos de 3 passos não evidenciaram redução da resistência de união quando a resina composta foi inserida tardiamente. Já os sistemas adesivos de 2 passos tiveram sensível redução dos valores de resistência de união. A redução ficou em torno de 30,24% para SB, 27,19% para OSP e 28,21% para B1. Conclusão: Cuidado especial deve ser tomado durante o uso de sistemas adesivos convencionais de 2 passos. É aconselhável que a resina composta seja inserida e polimerizada imediatamente após a conclusão do procedimento adesivo.


Introduction: Etch-and-rinse adhesive systems are characterized by the dental acid etching previously to the monomer application. These materials can be classified as 3-step (when primer and bond are applied separately) or 2-step (when the primer and bond functions are carried out by a single component). Objective: To determine the influence of immediate or delayed insertion of restorative material on the values of bond strength of 2-step and 3-step etch-and-rinse adhesive systems using the microtensile test. Material and methods: Bovine incisors were used, which had its vestibular surface abraded to obtain a flat dentin surface. 3-step (Scotchbond Multi-Purpose ? SMP; Optibond FL ? OFL; Bond-It ? BIT) and 2-step (Single-Bond ? SB; Optibond Solo Plus ? OSP; Bond-1 ? B1) etch-and-rinse adhesive systems were used, and composite resin (Z-350) was adhered to this substrate at two different times: immediately and later (after 24 hours). Procedures were performed with simulated physiological pulpal pressure. Results were submitted to statistical analysis through Anova and Tukey?s test (p < 0.05). Results: When the composite resin was immediately inserted all the adhesive systems showed similar results. 3-step adhesive systems did not show reduction in bond strength values related to delayed insertion of composite. On the other hand, 2-step adhesive systems showed significant reduction in the values of bond strength. Reduction was around 30.24% to SB, 27.19% to OSP and 28.21% to B1. Conclusion: 2-step etch-and-rinse adhesive systems should be used very carefully. It is advisable to insert and polymerize the composite resin immediately after the conclusion of adhesive procedure.

SELECTION OF CITATIONS
SEARCH DETAIL